In this podcast episode, we discuss power distribution and some practical tips about three-phase, single-phase, and split-phase power.

The power company generates three-phase power; a power pole transformer typically has three current-carrying conductors. Each phase of power runs at 60 Hz and generates a sine wave. That sine wave peaks and valleys in a wavy formation. Power is generated in a rotating magnetic field, so it is helpful to think of a sine wave as a variation of a circle.

Transformers take high voltage and bring it down to 120V split-phase via a winding on the left, a winding on the right, and a neutral tap. The split sine waves are exactly 180 degrees out of phase; they are direct opposites, and they will intersect and both be "off" at the same time. The center is neutral. This 120V split-phase power results in 240V total; therefore, we can use them in 240V applications. Split single-phase motors require a capacitor.

Three-phase power uses all three legs of power, and the sine waves are 120 degrees out of phase with each other. In three-phase power, only one wave will be "off" at any point in time. Three-phase power is a more efficient means of running motors; split single-phase power is relatively inefficient and requires a capacitor. However, reverse-phasing is a possibility and may run motors backward, causing damage. The most common type of three-phase transformer uses the wye configuration and works for 208V applications.

Bryan also discusses:

*   Wye vs. delta configuration
*   Delta configuration high leg
*   Start assistance and capacitors
*   Residential vs. commercial applications
*   Capacitor failure
*   277V and 480V applications
*   Replacing single-phase with three-phase power or vice versa
*   Three-phase condensers with single-phase air handlers

######  